The list of specifications may or may not be confidentialThese specifications are confidential and are the exclusive Intellectual Property of pdView Pty Ltd.

Renewable bid allocation - no FCAS

Background

...

no FCAS

...

Inputs

Information

Source

Description

SRMC+

Solver (any upstream process would do however the solver already calculates this liability).

This is the static SRMC plus the Raise Contingency FCAS liability (which is usually very small).

FRRP

User selected price forecast source

The forecast energy price

TPBmin and TPBmax

Trader parameters

The upper and lower pricebands that are meant to span the flat area of the supply curve that represents the bulk of the SRMC of the regions renewable plant.

Constraint_status

MMS.dispatch_local_price

Contraint_status is equal to 1 if local_price_adjustment is positive and represents the unit is at risk of being constrained OFF, 0 means there are no binding constraints for that unit and -1 means that the local_price_adjustment is negative and represents the unit is at risk of being constrained ON.

max_capacity (MC)

MMS.dudetail

The volume to allocate.

...